Driver LCI 150W 350/500/700/1050mA OTD EC

TEC outdoor series

Product description

  • Independent fixed output LED Driver
  • Constant current LED Driver
  • Output current 350, 500, 700 or 1,050 mA
  • Max. output power 150 W
  • Nominal life-time of 50,000 h (at max ta 55 °C with a failure rate ≤ 0.2 % per 1,000 h)
  • For luminaires of protection class I and protection class II
  • Temperature protection as per EN 61347-2-13 C5e

Properties

  • Robust aluminium casing
  • Type of protection IP67

Functions

  • Overtemperature protection
  • Overload protection
  • Short-circuit protection
  • No-load protection
  • Burst protection voltage up to 1.2 kV
  • Surge protection voltage up to 4 kV (L to N)
  • Surge protection voltage up to 6 kV (L/N to earth)
Autoscroll for tables
Ordering data
Type Article number Pack­ag­ing, carton Pack­ag­ing, low volume Pack­ag­ing, high volume Weight per pc.
LCI 150 W 350mA OTD EC 87500334 10 pc(s). 60 pc(s). 400 pc(s). 0.835 kg
LCI 150 W 500mA OTD EC 87500335 10 pc(s). 60 pc(s). 400 pc(s). 0.835 kg
LCI 150 W 700mA OTD EC 87500336 10 pc(s). 60 pc(s). 400 pc(s). 0.942 kg
LCI 150W 1050mA OTD EC 28000653 10 pc(s). 60 pc(s). 400 pc(s). 0.920 kg
Luminaire types:
Downlights
High bay luminaires
Linear luminaires
Wide-area luminaires (in-built, remote, pendant)
Approval marks:
IP67
110
MM
Short Circuit Proof without safety insulation
Independent gear
CE
RoHs
Technical data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
Rated current (at 230 V, 50 Hz) 0.79 A
Mains frequency 50 / 60 Hz
Leakage current (at 230 V, 50 Hz, full load) < 500 µA
Max. input power 165 W
Max. input power for1,050 mA 174 W
Output power range 75 – 150 W
THD (at 230 V, 50 Hz, full load) < 10 %
THD (at 230 V, 50 Hz, min. load) < 10 %
Output current tolerance (1) ± 5 %
Typ. current ripple (at 230 V, 50 Hz, full load) ± 5 %
Turn on time (at 230 V, 50 Hz, full load) ≤ 0.4 s
Turn off time (at 230 V, 50 Hz, full load) ≤ 0.1 s
Hold on time at power failure 0 s
Ambient temperature ta -40 ... +55 °C
Ambient temperature ta (at life-time 50,000 h) 55 °C
Max. casing temperature tc 85 °C
Storage temperature ts -40 ... +80 °C
Dimensions L x W x H 236.6 x 60 x 34 mm
Autoscroll for tables
Specific technical data
Type Output current (1) Power factor at full load (2) Ef­fi­cien­cy at full load (2) Power factor at min. load (2) Ef­fi­cien­cy at min. load (2) Min. forward voltage (2) Max. for­ward volt­age (2) Max. output voltage (2) Max. peak output current (2)
LCI 150 W 350mA OTD EC 350 mA 0.99 91 % 0.95 91 % 214 V 429 V 500 V 390 mA
LCI 150 W 500mA OTD EC 500 mA 0.99 91 % 0.95 90 % 150 V 300 V 360 V 550 mA
LCI 150 W 700mA OTD EC 700 mA 0.99 91 % 0.95 90 % 107 V 214 V 250 V 770 mA
LCI 150W 1050mA OTD EC 1,050 mA 0.99 90 % 0.95 89 % 71 V 143 V 172 V 1,110 mA
Document      Size       Date       
Download all selected files Download all selected files
TALEXXconverter_LCI_150W_OTD_EC_en.pdf
Data sheet
1.14 MB 18/07/2016
Leaflet_Outdoor_EN_web.pdf
Leaflet – Outdoor
1.13 MB 15/12/2016
new
Certificates / declarations of conformity
Type      Article number      Certificates     
Certificates ()
Autoscroll for tables
CAD / RAY
Type Article number CAD Files
LCI 150 W 350mA OTD EC 87500334 CAD (1.9 MB)
LCI 150 W 500mA OTD EC 87500335 CAD (1.9 MB)
LCI 150 W 700mA OTD EC 87500336 CAD (1.9 MB)

Please choose one of the following modules

Autoscroll for tables
Ordering data
Type Article number Configuration
 
 