Driver LCI 100W 350/500/700/1050mA OTD EC

TEC outdoor series

Product description

  • Independent fixed output LED Driver
  • Constant current LED Driver
  • Output current 350, 500, 700 or 1,050 mA
  • Max. output power 100 W
  • Nominal life-time of 50,000 h (at max ta 55 °C with a failure rate ≤ 0.2 % per 1,000 h)
  • For luminaires of protection class I and protection class II
  • Temperature protection as per EN 61347-2-13 C5e

Properties

  • Robust aluminium casing
  • Type of protection IP67

Functions

  • Overtemperature protection
  • Overload protection
  • Short-circuit protection
  • No-load protection
  • Burst protection voltage up to 1.2 kV
  • Surge protection voltage up to 4 kV (L to N)
  • Surge protection voltage up to 6 kV (L/N to earth)
Autoscroll for tables
Ordering data
Type Article number Pack­ag­ing, carton Pack­ag­ing, low volume Pack­ag­ing, high volume Weight per pc.
LCI 100 W 350mA OTD EC 87500331 10 pc(s). 80 pc(s). 400 pc(s). 0.755 kg
LCI 100 W 500mA OTD EC 87500332 10 pc(s). 80 pc(s). 400 pc(s). 0.755 kg
LCI 100 W 700mA OTD EC 87500333 10 pc(s). 80 pc(s). 400 pc(s). 0.755 kg
LCI 100W 1050mA OTD EC 28000652 10 pc(s). 80 pc(s). 400 pc(s). 0.788 kg
Luminaire types:
Downlights
High bay luminaires
Linear luminaires
Wide-area luminaires (in-built, remote, pendant)
Approval marks:
IP67
110
MM
Short Circuit Proof without safety insulation
Independent gear
CE
RoHs
Technical data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
Rated current (at 230 V, 50 Hz) 0.6 A
Mains frequency 50 / 60 Hz
Leakage current (at 230 V, 50 Hz, full load) < 500 µA
Max. input power 115 W
Max. input power for1,050 mA 118 W
Output power range 50 – 100 W
THD (at 230 V, 50 Hz, full load) < 10 %
THD (at 230 V, 50 Hz, min. load) < 15 %
Output current tolerance (1) ± 5 %
Typ. current ripple (at 230 V, 50 Hz, full load) ± 5 %
Turn on time (at 230 V, 50 Hz, full load) ≤ 0.2 s
Turn off time (at 230 V, 50 Hz, full load) ≤ 0.1 s
Hold on time at power failure 0 s
Ambient temperature ta -40 ... +55 °C
Ambient temperature ta (at life-time 50,000 h) 55 °C
Max. casing temperature tc 85 °C
Storage temperature ts -40 ... +80 °C
Dimensions L x W x H 242.6 x 52 x 32 mm
Autoscroll for tables
Specific technical data
Type Output current (1) Power factor at full load (2) Ef­fi­cien­cy at full load (2) Power factor at min. load (2) Ef­fi­cien­cy at min. load (2) Min. forward voltage (2) Max. for­ward volt­age (2) Max. output voltage (2) Max. peak output current (2)
LCI 100 W 350mA OTD EC 350 mA 0.98 91 % 0.96 89 % 143 V 286 V 343 V 370 mA
LCI 100 W 500mA OTD EC 500 mA 0.99 90 % 0.95 88 % 100 V 200 V 240 V 530 mA
LCI 100 W 700mA OTD EC 700 mA 0.98 90 % 0.95 86 % 71 V 143 V 171 V 740 mA
LCI 100W 1050mA OTD EC 1,050 mA 0.98 90 % 0.95 85 % 47 V 96 V 116 V 1,110 mA
Document      Size       Date       
Download all selected files Download all selected files
TALEXXconverter_LCI_100W_OTD_EC_en.pdf
Data sheet
1.15 MB 18/07/2016
Leaflet_Outdoor_EN_web.pdf
Leaflet – Outdoor
1.13 MB 15/12/2016
new
Certificates / declarations of conformity
Type      Article number      Certificates     
Certificates ()
Autoscroll for tables
CAD / RAY
Type Article number CAD Files
LCI 100 W 350mA OTD EC 87500331 CAD (1.7 MB)
LCI 100 W 500mA OTD EC 87500332 CAD (1.7 MB)
LCI 100 W 700mA OTD EC 87500333 CAD (1.7 MB)

Please choose one of the following modules

Autoscroll for tables
Ordering data
Type Article number Configuration
 
 
Visiting from the US or Canada?
Go to our dedicated site.
http://www.tridonic.us or stay on tridonic.com