PC T5 TEC lp, 14 – 28 W

PC TEC T5

Product description

  • CELMA Energy Efficiency Index A2
  • Nominal life-time up to 30,000 h (at ta 50 °C with a failure rate ≤ 0.3 % per 1,000 h)
  • Large temperature range (for values see table)
  • Lamp preheating for min. 30,000 starts without replacement of lamps (15,000 for 1x14 W application)
  • Automatic start after replacement of defective lamps
  • Safety shutdown of defective lamps and at end of lamp life
  • Temperature protection as per EN 61347-2-3 C5e
Autoscroll for tables
Ordering data
Type Article number Packaging, carton Packaging, low volume Packaging, high volume Weight per pc.
For luminaires with 1 lamp
PC 1x14 T5 TEC lp 87500211 50 pc(s). 1,050 pc(s). 3,150 pc(s). 0.112 kg
PC 1x21 T5 TEC lp 87500217 50 pc(s). 1,050 pc(s). 3,150 pc(s). 0.121 kg
PC 1x28 T5 TEC lp 87500215 50 pc(s). 1,050 pc(s). 3,150 pc(s). 0.121 kg
For luminaires with 2 lamps
PC 2x14 T5 TEC lp 87500212 50 pc(s). 900 pc(s). 2,700 pc(s). 0.155 kg
PC 2x28 T5 TEC lp 87500216 50 pc(s). 900 pc(s). 2,700 pc(s). 0.176 kg
For luminaires with 3 lamps
PC 3x14 T5 TEC lp 87500213 50 pc(s). 900 pc(s). 2,700 pc(s). 0.164 kg
For luminaires with 4 lamps
PC 4x14 T5 TEC lp 87500214 50 pc(s). 900 pc(s). 2,700 pc(s). 0.176 kg
Lamp types:
T5
Approval marks:
EAC
CCC
RCM
ÖVE
CE
RoHs
Technical data
Mains voltage range 220 – 240 V
AC voltage range 198 – 264 V
Mains frequency 50 / 60 Hz
Overvoltage protection 320 V AC, 1 h
Time to light ≤ 2 s
Operating frequency ≥ 40 kHz
Type of protection IP20
Autoscroll for tables
Specific technical data
Lamp wattage Lamp type Type Article number Dimensions
L x W x H
Hole spacing D Lamp power Circuit power EEI Current at 50 Hz λ at 50 Hz tc point max. Ambient tem­pera­ture ta tc/ta for ≥ 30,000 h
220 V 240 V 220 V 240 V
For luminaires with 1 lamp
1 x 14 W T16 (T5) PC 1x14 T5 TEC lp 87500211 230 x 30 x 21 mm 220 mm 13.7 W 16.5 W A2 0.07 A 0.07 A 0.95 0.95 60 °C -10 ... +50 °C 60/50 °C
1 x 21 W T16 (T5) PC 1x21 T5 TEC lp 87500217 230 x 30 x 21 mm 220 mm 20.7 W 23.5 W A2 0.11 A 0.11 A 0.96 0.96 60 °C -10 ... +50 °C 60/50 °C
1 x 28 W T16 (T5) PC 1x28 T5 TEC lp 87500215 230 x 30 x 21 mm 220 mm 27.8 W 31.5 W A2 0.14 A 0.14 A 0.97 0.97 65 °C -10 ... +50 °C 65/50 °C
For luminaires with 2 lamps
2 x 14 W T16 (T5) PC 2x14 T5 TEC lp 87500212 280 x 30 x 21 mm 270 mm 27.4 W 31.0 W A2 0.14 A 0.14 A 0.97 0.97 60 °C -10 ... +50 °C 60/50 °C
2 x 28 W T16 (T5) PC 2x28 T5 TEC lp 87500216 280 x 30 x 21 mm 270 mm 55.6 W 61.5 W A2 0.26 A 0.26 A 0.98 0.98 70 °C -10 ... +50 °C 70/50 °C
For luminaires with 3 lamps
3 x 14 W T16 (T5) PC 3x14 T5 TEC lp 87500213 280 x 30 x 21 mm 270 mm 41.1 W 46.0 W A2 0.21 A 0.21 A 0.97 0.97 65 °C -10 ... +50 °C 65/50 °C
For luminaires with 4 lamps
4 x 14 W T16 (T5) PC 4x14 T5 TEC lp 87500214 280 x 30 x 21 mm 270 mm 54.8 W 61.0 W A2 0.27 A 0.27 A 0.98 0.98 70 °C -10 ... +50 °C 70/50 °C
Document      Size       Date       
Download all selected files Download all selected files
PC_T5_TEC_lp_en.pdf
Data sheet
1.01 MB 21/12/2015
Ballast_Lamp_Matrix.pdf
Lamp matrix for ballasts
107 KB 09/10/2014
Certificates / declarations of conformity
Type      Article number      Certificates     
Certificates ()
Autoscroll for tables
CAD / RAY
Type Article number CAD Files
PC 1x14 T5 TEC lp 87500211 CAD (516.0 KB)
PC 1x21 T5 TEC lp 87500217 CAD (516.0 KB)
PC 1x28 T5 TEC lp 87500215 CAD (516.0 KB)
PC 2x14 T5 TEC lp 87500212 CAD (466.1 KB)
PC 2x28 T5 TEC lp 87500216 CAD (466.1 KB)
PC 3x14 T5 TEC lp 87500213 CAD (514.0 KB)
PC 4x14 T5 TEC lp 87500214 CAD (514.0 KB)

Please choose one of the following modules

Autoscroll for tables
Ordering data
Type Article number Configuration