RSS feedsRSS feeds Send page via emailSend page via email Print pagePrint page Text size Smaller text sizeSmaller text sizeSmaller text sizeLarger text sizeLarger text sizeLarger text size

Fixed-output


TE-DC 2 F101, 100 – 300 VA 230 – 240/12 V 0/50/60 Hz

Fixed output

 

zoom image
TA_NVT_F_TE_DC_D101_F101


zoom image
TA_NVT_M_DC


Product description

  • Independent device with integrated cable clamp and terminal cover
  • Constant output voltage
  • For emergency lighting systems as per EN 50172
  • Short-circuit shutdown feature with automatic restart
  • With soft start
  • Overtemperature and overload protection by reducing power and automatic restart
  • Quiet operation even when dimmed
  • Suitable for cable lengths up to 20 m
  • Double assignment of the terminal possible
  • Practical individual packaging with assembly instructions
  • Rapid installation of the cable clamp, no tools required
  • Not suitable for operation with MR16 LED bulbs
  • Order information
  • Common data
  • Technical data
  • Downloads
  • Images
  • Links
  • Accessories




Ordering data
TypeArticle numberLamp wattageDimensions L x W x HDistance between mounting holes (D)Dimming
TE-DC 2 0300 F101 white86458505100 – 300 VA254 x 147 x 59 mm218 – 226 mmnot provided (fixed output)
TE-DC 2 0300 F101 grey86458503100 – 300 VA254 x 147 x 59 mm218 – 226 mmnot provided (fixed output)

Packaging: 10 pieces/carton, 120 pieces/pallet

Ordering data
TypeArticle numberLamp wattageDimensions L x W x HDistance between mounting holes (D)Dimming
TE-DC 2 0300 F101 white86458505100 – 300 VA254 x 147 x 59 mm218 – 226 mmnot provided (fixed output)
TE-DC 2 0300 F101 grey86458503100 – 300 VA254 x 147 x 59 mm218 – 226 mmnot provided (fixed output)

Packaging: 10 pieces/carton, 120 pieces/pallet

Lamp types:
QR-CBC 51

Approval marks:
unabh-VGSC2120MMShort Circuit ProofCEENEC11RoHs

Technical data
Protection classII
Mains frequency0 / 50 / 60 Hz
Efficiency> 90 %
λ0.99
Power circuitrydigital
Specific technical data
TypeRated supply voltage ACRated supply voltage DCRated current (at 230 V 50 Hz)Secondary voltage (1)DC lamp outputAmbient temperature taMax. casing temperatureCurrent monitorSoft-startWeight per pcs.Output terminal
TE-DC 2 0300 F101230 – 240 V230 – 240 V1.45 A11.9 V70 %-20 ... +35 °C100 °Cyesyes0.8 kg2-pin, screw terminal
TE-DC 2 0300 F101230 – 240 V230 – 240 V1.45 A11.9 V70 %-20 ... +35 °C100 °Cyesyes0.8 kg2-pin, screw terminal

(1) Constant output voltage.


Document      Size       Date       
DS_TE_DC_2_F101_en.pdf
Data sheet
1,12 MB 20/01/2012
new
Mounting_TE-DC_2_0300_F101_en.pdf
Mounting
564,15 KB 01/01/2010
Download selected files Download selected files

Further information